Summary of Topics s1017_11_sum.htmlSummary of Topics
This new Eleventh edition of ANSI/UL 1017 dated March 26, 2025 includes the following changes in requirements: Double insulation: Waiving overload test on motors moving air only; Addition of requirements for pin and sleeve terminals; Clarification of allowance for 18-inch cord length; Button-cell lithium batteries; Updates for motor polymeric motor insulation systems; Drop impact test for removable reservoirs; Suitability of motor protectors operating during abnormal conditions; Removal of polarization instructions from the Important Safeguards for products with 18 inch cord; Interlock endurance test; Attachment identification marking; General purpose transformer testing; Update safety critical function tables due to revision to UL 2595; Clarify location for blocked inlet condition of the severe conditions test (air inlet or end of hose); Clarification of defeated component test for polymeric fluid handling components for appliances with attachments containing liquids; Clarification of the thermal aging requirement of 5.21.10; Corrections and clarification of the PFHC requirements of 5.12.8 and the flowchart (Figure F.1) from Annex F Clarification of switches for steam cleaning attachments; Update attachment plug rating to align with appliance rating; Update supplier list of test carpet; Add UL 840 as alternative to meeting spacing requirements; 550 °C Glow Wire Test in place of HB; PTI test as alternative to CTI; Cord length of household extraction type floor cleaners; Ash vacuum cleaners; Replace "dielectric voltage-withstand" with "electric strength"; Revise requirement for grounding and bonding per CSA comment; Eliminate exceptions; Updated references to UL, CSA and IEC standards; Clarification of non-user-replaceable LED light sources in 4.13.5; Correction to Table 5.3; Clarification of the Strength of handles test; Utility Vacuum Cleaner Definition/Instructions; Operation of protective devices during normal operation; Normal Operation Duty Cycle for products with a timer; Mechanical Hazard proposal; Mechanical Valve Operation for input test; Cord and conduction AWG units in Table 12.1 and Table 4.9; Motors without a horsepower rating; Battery-operated appliances – Disconnection before cleaning or servicing; Waiving the stalled rotor condition of 5.21.7 for electronically commutated motors; Clarifying the compliance criteria for flooding of live parts test of 5.12.5; Allow digital manuals; Testing on hard surfaces; Update the Scope to reflect the products covered; Use of mean flow in lieu of mean wattage for normal operation; Class H insulation temperature limits; Wire color coding; Updated reference to information technology equipment standards; Attachment plug rating for steam cleaners; Robotic floor care; Docking Station Supply Cord Type and Length; and Correction to conversion in B3.2.