1.1 These requirements cover electrically operated single and multiple station carbon monoxide (CO) alarms intended for protection in ordinary indoor locations and unconditioned areas, per applicable governing laws, codes, and standards. This includes, but is not limited to, of dwelling units, including recreational vehicles, mobile homes, commercial vehicles, and recreational boats with enclosed accommodation spaces and cockpit areas.
1.2 Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. Carbon monoxide alarms are intended to alarm at carbon monoxide levels below those that cause a loss of ability to react to the dangers of carbon monoxide exposure. See , Part A, Alarm – carbon monoxide concentration and response time.
1.3 Carbon monoxide alarms covered by this standard are not intended to alarm when exposed to long-term, low-level carbon monoxide exposures or slightly higher short-term transient carbon monoxide exposures, possibly caused by air pollution and/or properly installed/maintained fuel-fired appliances and fireplaces. See , Part B, False alarm resistance specifications.
1.4 These requirements, where applicable, also cover all remote accessories that may be connected to or are intended to be employed with a single or multiple station carbon monoxide alarm. See 1.
1.5 This standard does not cover the following:
a) Single and multiple station smoke alarms that are covered by the Standard for Smoke Alarms, UL 217, or the Standard for Smoke Alarms, ULC-S531.
b) Smoke alarms of the nonself-contained type that are intended for connection to a household or industrial system control unit. These are included in the Standard for Smoke Detectors for Fire Alarm Systems, UL 268, or the Standard for Smoke Detectors, Fire Alarm, ULC-S529.
c) Mechanically operated single and multiple station fire alarm devices that are specified in the Standard for Single and Multiple Station Heat Alarms, UL 539, or the Standard for Heat Actuated Fire Detectors, Fire Alarm, ULC-S530.
d) Heat alarms whose requirements are covered in the Standard for Heat Detectors for Fire Protective Signaling Systems, UL 521, or the Standard for Lined Building Protection Fire Hose, ULC-530.
e) Carbon monoxide gas detectors intended for use in hazardous locations as defined in the U.S. Coast Guard Electrical Engineering Regulations.
This revision of ANSI/UL 2034 dated August 7, 2024 includes a correction to a cross-reference to 89.2(l) in Section 69.
RevisionsRed Line Std. (2)
CSDS Proposals (1)
CSDS Proposals
An electronic document associated with a UL Standard for Safety or Outline of Investigation, and issued by UL to propose:
UL LLC CRD (0)
Other Updates (0)
Referenced Standards (33)
Reverse Referenced Standards (4)
The cost to purchase this Standard varies depending on whether you are ordering a hardcopy, PDF or combination of the two. We also offer two different types of subscriptions: a one year and a three year.
You will be able to choose your purchase options on the following pages.
To serve you better, please update your account details.
Sample