1.1 These requirements cover telecommunications-circuit accessories, such as jack and plug assemblies, quick-connect terminal assemblies, telephone wall plates, telephone extension cords, cross-connect terminal-block assemblies, maintenance terminal modules, terminal enclosures, cable-splice enclosures, network-interface devices, wire-guide assemblies, and connector boxes.
1.2 These devices are intended to be used in telecommunications networks that have an operating root-mean-square (rms) voltage to ground less than 150 volts and installed or used in accordance with the National Electrical Code, ANSI/NFPA 70.
1.3 These requirements do not cover telephone equipment such as telephone answering devices, residential telephone instruments, telephone dialers, cordless phones, key systems, and private-branch exchange equipment that is covered by the Standard for Information Technology Equipment – Safety – Part I: General Requirements, UL 60950-1, or the Standard for Audio/Video, Information and Communication Technology Equipment – Part 1: Safety Requirements, UL 62368-1.  Also, these requirements do not cover:
- a) Telephone protectors that are covered by the Standard for Protectors for Paired-Conductor Communications Circuits, UL 497, and 
- b) Secondary protectors that are covered by the Standard for Secondary Protectors for Communications Circuits, UL 497A. 
- c) Information Technology and Communications Equipment Cabinets, Enclosure and Rack Systems are investigated to the Standard for Information Technology Equipment – Safety – Part 1, UL 60950-1 or Audio/Video, Information and Communication Technology Equipment – Part 1: Safety Requirements, UL 62368-1 Cabinet, Enclosure and Rack Systems, UL 2416. 
1.4 These requirements do not cover receiver/transmitter-type devices. Equipment of this type is covered by the Standard for Audio, Video and Similar Electronic Apparatus – Safety Requirements, UL 60065; or the Standard for Audio/Video, Information and Communication Technology Equipment – Part 1: Safety Requirements, UL 62368-1.
1.5 These requirements may be used, directly or by reference, to investigate portions of other equipment, not classified as telecommunications-equipment accessories, that may be connected to a telecommunications network, insofar as they may be applicable to such equipment.
1.6 These requirements do not cover wires and cables intended to be permanently installed in a building in accordance with Article 800 of the National Electrical Code, ANSI/NFPA 70.
1.7 These requirements do not cover cable assemblies intended for powering or charging Audio/Video, information and communication equipment using a USB-C interface.