Standard 1331, Edition 1
UL 1331

STATION INLETS AND OUTLETS

UL Bulletin Edition 1 Published Date: June 30, 2005 Last Revision: February 05, 2020

$203.00-$254.00

Summary of Topics b1331_1_20050630_sum.html

Subject 1331

Bulletin Dated: June 30, 2005

SUMMARY OF TOPICS

The following are changes in requirements to the proposed First Edition of UL 1331 from UL's Subject 1331 bulletin dated September 3, 2004:

1. Scope - Add paragraph 1.2 to clarify the scope of the standard.

2. Glossary Terms - Add new terms to the Glossary.

3. Secondary Valve - Revise paragraph 4.3 to add provision for optional secondary valve.

4. Assembly - Delete paragraph 4.8 since requirement is out of date.

5. Connections - Revise paragraph 4.12 to prohibit flared and compression-type connections.

6. Hydrostatic Strength Test - Clarify samples used for this test.

7. Performance, General - Clarify performance requirements.

8. Station Inlets and Outlets for Manufactured Assemblies - Addition of several tests to address station inlets and outlets for manufactured assemblies.

9. Editorial Revisions - Revisions to paragraphs 4.4, 4.10, 4.11, 8.3, and 8.4 to clarify the requirements.

COMMENTS DUE: AUGUST 30, 2005

Back to Standard 1331, Edition 1

The cost to purchase this Standard varies depending on whether you are ordering a hardcopy, PDF or combination of the two. We also offer two different types of subscriptions: a one year and a three year.

You will be able to choose your purchase options on the following pages.

×
×
×
×
×

You have one or more subscriptions that will expire soon.

×

You have one or more licenses to assign

×

Additional information required

To serve you better, please update your account details.

Featured Standards


Recently Published











Coming Soon

UL 48
Electrical Signs
Revision Pages

UL/ULC 25
Meters for Flammable and Combustible Liquids and LP-Gas
Revision Pages

UL 155
Tests for Fire Resistance of Vault and File Room Doors
Revision Pages

UL 310
Electrical Quick-Connect Terminals
New Edition

UL 19
Lined Fire Hose and Hose Assemblies
Revision Pages

UL 104
Elevator Door Locking Devices and Door or Gate Closed Detection Means
New Edition

UL 217
Smoke Alarms
Revision Pages

UL 294
Access Control System Units
Revision Pages
×